CMMC Phase 2 is suspended (July 13, 2026). What still applies →

FAR 52.204-21: 15 Basic Safeguarding Requirements

The baseline cybersecurity rule for Federal Contract Information (FCI), mapped paragraph by paragraph to the 17 CMMC Level 1 practices, NIST SP 800-171 Rev. 2 weights, and concrete audit evidence.

By Shangyi Duan · Verified against 48 CFR 52.204-21 (Nov 2021) on November 24, 2026 · Not legal advice

Direct answer: FAR 52.204-21 (Basic Safeguarding of Covered Contractor Information Systems) mandates 15 minimum security controls in paragraph (b)(1)(i)–(xv) for any federal prime or subcontractor whose systems process, store, or transmit non-public Federal Contract Information (FCI). Those 15 paragraphs map to 17 CMMC Level 1 practices (worth 63 of 313 Level 2 SPRS points) and remain active despite the July 2026 CMMC Phase 2 pause.

Download the checklist or run the self-check below

Skip reading raw CFR PDFs during an internal audit. Grab the ready-to-fill Excel workbook (all 15 paragraphs, all 17 mapped Level 1 IDs, example evidence artifacts, owner and review-date columns) or mark each requirement directly in your browser. Nothing leaves your device and no email address is requested.

2-sheet workbook: 17 mapped control rows + scoping/flow-down summary · No login required

Interactive 15-requirement self-check

Mark each paragraph Met only if you can hand a contracting officer or assessor documented proof today. Paragraph (b)(1)(ix) covers three separate physical-security controls, so mark it Met only when visitor escorts, physical access logs, and badge or key controls are all operating.

48 CFR 52.204-21(b)(1)(i)–(xv)

15 paragraphs → 17 L1 controls

FAR 52.204-21 to CMMC Level 1 and NIST SP 800-171 mapping

Contractors often get tripped up by the count mismatch: the regulation lists 15 numbered paragraphs, whereas CMMC Level 1 checks 17 practices. Paragraph (b)(1)(ix) combines three distinct physical-security rules into one clause, and 32 CFR 170.15 separates them into PE.L1-3.10.3, PE.L1-3.10.4, and PE.L1-3.10.5.

Five of these rows (3.1.20, 3.1.22, 3.10.3, 3.10.4, and 3.10.5) are also legally barred from a Conditional Level 2 POA&M under 32 CFR 170.21(a)(2)(iii). Closing them early prevents surprises if your prime later flows down CUI work.

Clause Paragraph CMMC L1 / NIST 800-171 L2 Pts Required Action Concrete Audit Evidence
(b)(1)(i)AC.L1-3.1.15Limit system access to authorized users, processes, and devices.Entra ID / Active Directory roster, device inventory, offboarding tickets.
(b)(1)(ii)AC.L1-3.1.25Limit access to the transactions and functions each user is permitted to execute.Role-based access matrix, separate admin accounts, SharePoint folder ACLs.
(b)(1)(iii)AC.L1-3.1.20No POA&M1Verify and control or limit connections to external information systems.External-system policy, approved SaaS vendor list, BYOD and VPN rules.
(b)(1)(iv)AC.L1-3.1.22No POA&M1Control information posted or processed on publicly accessible systems.Website and social-media approval workflow confirming zero FCI release.
(b)(1)(v)IA.L1-3.5.15Identify system users, processes acting on behalf of users, and devices.Unique named user IDs (no shared accounts), service account list, asset tags.
(b)(1)(vi)IA.L1-3.5.25Authenticate identities of users, processes, or devices before granting access.SSO/password policy screenshots, workstation login enforcement, MDM certificates.
(b)(1)(vii)MP.L1-3.8.35Sanitize or destroy media holding FCI before disposal or release for reuse.NIST SP 800-88 wipe SOP, recycler certificates of destruction, drive wipe logs.
(b)(1)(viii)PE.L1-3.10.15Limit physical access to systems, equipment, and operating environments.Keyholder/badge roster, locked server rack photos, office access procedure.
(b)(1)(ix)PE.L1-3.10.33.10.43.10.5No POA&M3 (1+1+1)Escort visitors and monitor activity; keep physical access logs; manage keys and badges.Visitor escort SOP, retained sign-in/badge logs, key/keycard inventory and revocation log.
(b)(1)(x)SC.L1-3.13.15Monitor, control, and protect communications at external and key internal boundaries.Firewall rule export, boundary diagram showing internet gateway and VLANs.
(b)(1)(xi)SC.L1-3.13.55Separate publicly accessible components into subnetworks isolated from internal LANs.DMZ or separate cloud web-hosting architecture diagram isolated from internal FCI.
(b)(1)(xii)SI.L1-3.14.15Identify, report, and correct information system flaws in a timely manner.Patch cadence policy, OS/app update logs, closed vulnerability tickets.
(b)(1)(xiii)SI.L1-3.14.25Provide protection from malicious code at appropriate system locations.Endpoint EDR or antivirus deployment dashboard covering every in-scope workstation and server.
(b)(1)(xiv)SI.L1-3.14.45Update malicious code protection mechanisms when new releases appear.EDR/AV automatic definition and engine update policy plus current status export.
(b)(1)(xv)SI.L1-3.14.53Run periodic system scans and real-time scans on downloaded or opened files.Weekly/daily scheduled scan config and real-time file-scanning status screenshot.

Total Level 2 SPRS weight of these 17 mapped controls: 63 points (11 five-point controls, 1 three-point control, and 5 one-point controls). See the worked Level 1 self-assessment example for how a 12-person machine shop documents each row.

Scope: FCI vs. CUI, flow-down, and when this clause is not enough

Do not confuse basic safeguarding with CUI protection. Check every solicitation and purchase order before assuming 15 controls are sufficient.

FactorBasic Safeguarding (48 CFR 52.204-21)CUI Safeguarding (DFARS 252.204-7012)
Data coveredFederal Contract Information (FCI): non-public information provided by or generated for the Government under a contract (drawings, schedules, non-public RFPs, delivery instructions).Controlled Unclassified Information (CUI) and Covered Defense Information (CDI), such as ITAR/export-controlled CAD files or technical data packages.
Controls required15 paragraphs (17 CMMC Level 1 practices).All 110 NIST SP 800-171 Rev. 2 controls plus 72-hour DIBNet cyber incident reporting and FedRAMP Moderate cloud rules.
Scoring & POA&MPass/fail only; all 17 practices must be Met; no POA&M allowed.Scored from 110 down to -203 in SPRS; limited 180-day POA&M rules under 32 CFR 170.21.
Subcontract flow-downMandatory under paragraph (c) for every subcontractor whose systems hold or transmit FCI, including commercial services — except purely COTS-only orders.Mandatory flow-down whenever CUI or CDI passes to a subcontractor.
Who does NOT need thisPurely COTS vendors selling unmodified commercial catalog items, and firms handling only public website data or basic payment invoices.Contractors handling FCI only (no CUI markings or DFARS 7012 clause).

Limitation to note: Paragraph (b)(2) explicitly states that meeting these 15 minimum controls does not relieve you from agency-specific safeguarding rules or CUI obligations. If your contract includes DFARS 252.204-7012 or 7019/7020, move directly to the 110-control SPRS calculator and our SPRS score guide.

Official references and further reading

Need all 110 CUI controls next?

Once these 15 basic controls are verified, you already hold 63 of the 313 points on the Level 2 scale. Score the remaining 93 requirements in your browser with zero signup.

Open the 110-control SPRS calculator

Frequently asked questions

What does FAR 52.204-21 require?

It mandates 15 basic cybersecurity controls in paragraph (b)(1)(i)–(xv) covering access limits, user authentication, media wiping, physical access, network separation, patching, and malware scanning on any contractor system that touches Federal Contract Information.

Why are there 15 paragraphs in the clause but 17 practices in CMMC Level 1?

Paragraph (b)(1)(ix) groups three physical-security obligations into one sentence: visitor escorts, physical access audit logs, and managing keys or badges. Under 32 CFR 170.15, CMMC Level 1 splits them into PE.L1-3.10.3, PE.L1-3.10.4, and PE.L1-3.10.5.

Who is exempt from these rules?

Contracts and subcontracts exclusively for commercially available off-the-shelf (COTS) items are exempt under FAR 4.1903 and paragraph (c). Publicly released documents and simple payment-processing records are also excluded from the FCI definition.

Does the July 2026 CMMC Phase 2 suspension pause basic safeguarding?

No. Only third-party C3PAO (Level 2) and DIBCAC (Level 3) contract requirements were paused on July 13, 2026. Basic FCI safeguarding and annual Level 1 self-assessments remain active; see current CMMC status for details.

Do I submit a numerical SPRS score for Level 1?

No. Level 1 records a binary compliance affirmation (all 17 practices Met) in SPRS with no POA&M allowed. Numerical scores from -203 to 110 apply only to the 110 NIST SP 800-171 CUI controls.

Related: 17-practice Level 1 checker · CMMC Level 1 overview · worked Level 1 example · DFARS 252.204-7012 (CUI) · 110-control checklist · SPRS score guide